Next: 5.5.1 Frequency and Amplitude
Up: 5. Frequency Dependent Simulation
Previous: 5.4 Extraction of the
  Contents
From the viewpoint of communication engineering, a ferroelectric
capacitor is a nonlinear and, as a consequence of hysteresis, time
variant system. Consequently, standard approaches for the analysis of
signal response in linear time invariant (LTI) systems cannot be
applied. Instead a more detailed analysis of the properties is
necessary. Actually, any signal response shows a strong dependence on
shape, amplitude and frequency of the input signal.
Subsections
Klaus Dragosits
2001-02-27